Line 40: Line 40:
  
 ^ USB/Serial device ^ Image ^Driver version ^Comments ^ ^ USB/Serial device ^ Image ^Driver version ^Comments ^
-| [[http://​plugable.com/​products/​pl2303-db9|Plugable USB to RS-232 DB9 Serial Adapter]] | {{:​mgl:​plugable.jpg|}}| [[http://​plugable.com/​drivers/​prolific|Prolific driver 1.5.1]] | Works with the Topcon but **not** ​with the Minolta. This seems to be some issue with the driver ​not handling 7 bit serial communication properly (it for instance returns values ​with the high bit set when they should be 0). +| [[http://​plugable.com/​products/​pl2303-db9|Plugable USB to RS-232 DB9 Serial Adapter]] | {{:​mgl:​plugable.jpg|}}| [[http://​plugable.com/​drivers/​prolific|Prolific driver 1.5.1]] ​[[https://​www.prolific.com.tw/​admin/​Technology/​GetFile.ashx?​fileID=1509 ​Prolific driver, compatible ​with Sonoma]] | Update: works with Minolta ​CS100a as well, with the right driver. Works with the Topcon ​
-| [[http://​www.tripplite.com/​high-speed-usb-to-serial-adapter-keyspan~USA19HS/​|Keyspan High-Speed USB to Serial Adapter USA-19HS]] | {{:​{{:​mgl:​keyspan.jpg|}} | [[https://​assets.tripplite.com/​drivers/​usa-19hs-driver-v4-mac-os-x-10.9-10.11.zip |Mac OS X 10.9.x to 10.11.x Version 2.6 ]]{{:​gru:​keyspanusa_10.9_10.10_v4_signed.pkg.zip|Try this if that link is broken }} [[https://​www.tripplite.com/​support/​downloads/​|or look for '​USA-19HS'​ here]] | Works with Minolta CS100a. We used to use other versions of this device Keyspan USA-28 which worked with PR650 and a white translucent Keyspan USA-28X B which did **not** work |+| [[http://​www.tripplite.com/​high-speed-usb-to-serial-adapter-keyspan~USA19HS/​|Keyspan High-Speed USB to Serial Adapter USA-19HS]] | {{:​{{:​mgl:​keyspan.jpg|}} | [[https://​assets.tripplite.com/​drivers/​usa-19hs-driver-v4-mac-os-x-10.9-10.11.zip |Mac OS X 10.9.x to 10.11.x Version 2.6 ]]{{:​gru:​keyspanusa_10.9_10.10_v4_signed.pkg.zip|Try this if that link is broken }} [[https://​www.tripplite.com/​support/​downloads/​|or look for '​USA-19HS'​ here]] | Works with Minolta CS100a. We used to use other versions of this device Keyspan USA-28 which worked with PR650 and a white translucent Keyspan USA-28X B which did **not** work. The Keyspan USA website does not yet have support for OS Sonoma. ​|
  
 Typically you can just connect the USB/Serial device to the Serial cable of the photometer, but for the Topcon you will need a nullmodem connector between the two (this swaps the read/write lines for communication). It looks like this (remember this should **only** be necessary for Topcon). Typically you can just connect the USB/Serial device to the Serial cable of the photometer, but for the Topcon you will need a nullmodem connector between the two (this swaps the read/write lines for communication). It looks like this (remember this should **only** be necessary for Topcon).
Line 227: Line 227:
  
 The most important field of calib is the table field which holds the inverse lookup table to linearize the monitor. The most important field of calib is the table field which holds the inverse lookup table to linearize the monitor.
 +
 +===== Debugging =====
 +
 +  - For some reason, there are runs in which the gamma table doesn'​t change during the gamma measurement. I have found that rerunning moncalib, or waiting longer between the gammatable change and the photometer measurement (moncalib around L248) seems to alleviate this problem. ​